Validation of 10-year SAO OMI ozone profile (PROFOZ) product using Aura MLS measurements

Article

Publications

Complete Citation

Overview

Abstract

  • We validate the Ozone Monitoring Instrument (OMI) ozone profile (PROFOZ v0.9.3) product including ozone profiles between 0.22 and 261 hPa and stratospheric ozone columns (SOCs) down to 100, 215, and 261 hPa from October 2004 through December 2014 retrieved by the Smithsonian Astrophysical Observatory (SAO) algorithm against the latest Microwave Limb Sound (MLS) v4.2x data. We also evaluate the effects of OMI row anomaly (RA) on the retrieval by dividing the data set into before and after the occurrence of serious RA, i.e., pre-RA (2004-2008) and post-RA (2009-2014). During the pre-RA period, OMI ozone profiles agree very well with MLS data. After applying OMI averaging kernels to MLS data, the global mean biases (MBs) are within 3 % between 0.22 and 100 hPa, negative biases are within 3-9 % for lower layers, and the standard deviations (SDs) are 3.5-5 % from 1 to 40 hPa, 6-10 % for upper layers, and 5-20 % for lower layers. OMI shows biases dependent on latitude and solar zenith angle (SZA), but MBs and SDs are mostly within 10 % except for low and high altitudes of high latitudes and SZAs. Compared to the retrievals during the pre-RA period, OMI retrievals during the post-RA period degrade slightly between 5 and 261 hPa with MBs and SDs typically larger by 2-5 %, and degrade much more for pressure less than ˜ 5 hPa, with larger MBs by up to 8 % and SDs by up to 15 %, where the MBs are larger by 10-15 % south of 40° N due to the blockage effect of

Publication Date

  • 2018

Authors